nAIM Series (digital)

Part Number: D02691880, D14690880

Broad Range Vacuum Gauging

When measuring pressure over a large range and requiring exceptional accuracy throughout, broad range vacuum gauges are the ideal option. To guarantee the precision and control of your system, you need trustworthy vacuum gauges. The AIM Series Cold Cathode Gauge, the WRG Series Cold Cathode Combination Gauge, and the APG Series Pirani Gauge are some of our vacuum gauging options.

AIM Series Cold Cathode Gauge

The gaugehead and controller of the Edwards nAIM series active Inverted Magnetron vacuum gauges are housed in a single, small active device. These are the latest digital gauges, which have shown to be dependable and robust in a variety of settings, from industrial operations to research instrumentation.

The nAIM gauges provide a serial output, a changeable sensor tube, and a compact footprint for simple installation. It is expected that the digital gauges will work with the next active gauge controllers and displays as well as the next generation of Edwards instruments. Because of their lead-free construction, they are also fully RoHS compliant and have received approval from the CSA and C/US.

Category:
Enquiry

Features and Benefits

The functioning range of the wide-ranging supply voltage is 15 to 48 V DC.
Data about gauge identification can be stored by users through gauge naming.
Quick swapping out of tubes without prior calibration
Fast striking is ensured by a unique striker design, even in contaminated or high vacuum environments.
Version L with a low external magnetic field for delicate analytical instruments (patented)
Serial communications can function in a point-to-point or multidrop system with little overhead thanks to a straightforward ASCII, low latency query and command protocol.
Simple process control and interlocking with an adjustable open collector set-point output for RS485 at 9600 baud, 8 bits, 1 start bit, and 1 stop bit M

Specifications

General Product Information

Weight 0.810 kg
Supply Frequency DC Voltage

Environmental Conditions

Temperature Ambient Operation Max 333.15 K
Temperature Ambient Operation Min. 278.15 K
Temperature Ambient Storage Min. 273.15 K
Temperature Ambient Storage Max. 343.15 K

Classification

Product Pressure Range High Vacuum – 1*10-3 – 1*10-7 mbar


Ultra High Vacuum – 1*10-7 – 1*10-11 mbar


Principle Of Measurement Cold-cathode vacuum gauge (IM inverted magnetron)

Performance Data

Pressure Measurement Max. 1.00 Pa
Pressure Measurement Min.. 1.000 × 10⁻⁷ Pa

Operation Conditions – Limitations

Temperature Baking Max. (Elec. Removed) 423.15 K
Pressure Inlet Max Overpressure 1.000 × 10⁶ Pa

Connectivity – Communication Interface

Communication Interfaces Customer RS232 (serial)
Connection electrical comms interface connector DSUB 9-PIN – Male

Variants

Variant Gauges nAIM (standard variant digital AIM)

Variants

nAIM-I – RS485 NW25 – digital

Connection electrical comms interface connector DSUB 9-PIN – Male
Connection Vacuum Inlet Flange DN 25 ISO-KF (NW25)
Pressure Measurement Max. 1.00 Pa
Pressure Measurement Min.. 1.000 × 10⁻⁷ Pa

nAIM – RS232 NW25 – digital

Connection electrical comms interface connector DSUB 9-PIN – Male
Pressure Measurement Max. 1.00 Pa
Pressure Measurement Min.. 1.000 × 10⁻⁷ Pa

nAIM – RS232 DN 40 CF – digital

Connection electrical comms interface connector DSUB 9-PIN – Male
Connection Vacuum Inlet Flange DN 40 CF (2.75″)
Pressure Measurement Max. 1.00 Pa
Pressure Measurement Min.. 1.000 × 10⁻⁷ Pa

Instructions Manual

Digital Gauge Range Serial Communications-Instructions

nAIM Series (digital)-Instructions