7045 / 7100 – Heated

Part Number: W603200880, W603300880, W60990880

Precision Vacuum Gauging

The finest option for measuring and managing your process is a precision vacuum gauge. While these gauges are the most accurate, they only function in a limited pressure spectrum, in contrast to broad vacuum gauges. Edwards provides diaphragm gauges with ASG2 and capacitance gauges with the Barocel series.

Barocel Series Capacitance Manometer

The Edwards Barocel 7000 series is the most precise vacuum gauge we have ever offered. There are three primary models in the Barocel 7000 series: 7025m, 7025, and 7045/7100. These come with various flange configurations and a range of full-scales from 1000 to 0.1 mbar/torr (100 to 10 for the 7025m). This makes it possible to measure and control pressure for more than 70 years, and it makes system fitting easier.

Barocel Gauges were introduced in response to consumer demands for ever-increasing system control and measurement accuracy. We can provide exceptional performance and dependability with our ambient and heated options, so you can fit and forget it.

7045 / 7100 – Heated

The inbuilt heaters in these gauges maintain the gauges at predetermined temperatures by using the same measuring cell as the 7025. Two tiers of heated gauges have been used for applications involving harsh gases where condensation may be a problem. These provide you peace of mind that there won’t be condensates in the gauge that could harm your control network because they are heated to constant temperatures of either 45°C (7045) or 100°C (7100).

Category:
Enquiry

Features and Benefits

Outstanding accuracy and 0% steadiness in terms of performance
Improvement of the system – Easy integration for improved control with two set points
Adaptable fixes – From little to warm and all in between
Minimal ownership costs –No upkeep needed

Specifications

General Product Information

Connection Vacuum Inlet Flange DN 16 ISO-KF (NW16)
Supply Voltage DC 14-30V
Dimension Length 0.082 m
IP Rating IP40
Supply Frequency DC Voltage
Dimension Height 0.146 m
Dimension Width 0.082 m
Connection Power DSUB 15-PIN – Male
Recommended Controller TIC – Turbo & Instrument Controller – power and control

Environmental Conditions

Temperature Ambient Operation Max 313.15 K
Temperature Ambient Operation Min. 283.15 K
Temperature Ambient Storage Min. 253.15 K
Temperature Ambient Storage Max. 338.15 K

Classification

Product Pressure Range Rough Vacuum 1000 mbar – 1 mbar
Principle Of Measurement Capacitance diaphragm vacuum gauges

Performance Data

Measurement Uncertainty 0.15% ± temperature effect
Power Consumption Max 8W


<12W during heat up; <8W during operation


Pressure Measurement Max. 1.333 × 10⁵ Pa
Pressure Measurement Min.. 13.33 Pa

Material of Construction

Material Exposed To Vacuum Ceramics (Al2O3≥99.5%), Stainless steel AISI 316L

Operation Conditions – Limitations

Pressure Inlet Max Overpressure 6.000 × 10⁵ Pa
Temperature Baking Max. 383.15 K

Connectivity – Communication Interface

Communication Interfaces Customer 0-10 V (analog output – linear)


RS232 (serial)


Connection electrical comms interface connector DSUB 15-PIN – Male

Variants

Short Description Part Number Pressure Measurement Max. Connection Vacuum Inlet Flange
Barocel 7045 – 1000torr DN 16 ISO-KF W603211120 1.333 × 10⁵ Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 1000torr 8VCR W603211220 1.333 × 10⁵ Pa 8″ VCR Female
Barocel 7045 – 100torr DN 16 ISO-KF W603212120 13332.24 Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 100torr 8VCR W603212220 13332.24 Pa 8″ VCR Female
Barocel 7045 – 10torr DN 16 ISO-KF W603213120 1333.22 Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 10torr 8VCR W603213220 1333.22 Pa 8″ VCR Female
Barocel 7045 – 1torr DN 16 ISO-KF W603214120 133.32 Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 1torr 8VCR W603214220 133.32 Pa 8″ VCR Female
Barocel 7045 – 0.1torr DN 16 ISO-KF W603215120 13.33 Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 0.1torr 8VCR W603215220 13.33 Pa 8″ VCR Female
Barocel 7045 – 1000mbar DN 16 ISO-KF W603221120 1.000 × 10⁵ Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 1000mbar 8VCR W603221220 1.000 × 10⁵ Pa 8″ VCR Female
Barocel 7045 – 100mbar DN 16 ISO-KF W603222120 10000.00 Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 100mbar 8VCR W603222220 10000.00 Pa 8″ VCR Female
Barocel 7045 – 10mbar DN 16 ISO-KF W603223120 1000.00 Pa DN 16 ISO-KF (NW16)
Barocel 7045 – 10mbar 8VCR W603223220 1000.00 Pa 8″ VCR Female
Barocel 7045 – 1mbar DN 16 ISO-KF W603224120 100.00
Pa
DN 16 ISO-KF (NW16)
Barocel 7045 – 1mbar 8VCR W603224220 100.00
Pa
8″ VCR Female
Barocel 7045 – 0.1mbar DN 16 ISO-KF W603225120 10.00
Pa
DN 16 ISO-KF (NW16)
Barocel 7045 – 0.1mbar 8VCR W603225220 10.00
Pa
8″ VCR Female
Barocel 7100 – 1000torr DN 16 ISO-KF W603311120 1.333 × 10⁵
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 1000torr 8VCR W603311220 1.333 × 10⁵
Pa
8″ VCR Female
Barocel 7100 – 100torr DN 16 ISO-KF W603312120 13332.24
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 100torr 8VCR W603312220 13332.24
Pa
8″ VCR Female
Barocel 7100 – 10torr DN 16 ISO-KF W603313120 1333.22
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 10torr 8VCR W603313220 1333.22
Pa
8″ VCR Female
Barocel 7100 – 1torr DN 16 ISO-KF W603314120 133.32
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 1torr 8VCR W603314220 133.32
Pa
8″ VCR Female
Barocel 7100 – 0.1torr DN 16 ISO-KF W603315120 13.33
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 0.1torr 8VCR W603315220 13.33
Pa
8″ VCR Female
Barocel 7100 – 1000mbar DN 16 ISO-KF W603321120 1.000 × 10⁵
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 1000mbar 8VCR W603321220 1.000 × 10⁵
Pa
8″ VCR Female
Barocel 7100 – 100mbar DN 16 ISO-KF W603322120 10000.00
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 100mbar 8VCR W603322220 10000.00
Pa
8″ VCR Female
Barocel 7100 – 10mbar DN 16 ISO-KF W603323120 1000.00
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 10mbar 8VCR W603323220 1000.00
Pa
8″ VCR Female
Barocel 7100 – 1mbar DN 16 ISO-KF W603324120 100.00
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 1mbar 8VCR W603324220 100.00
Pa
8″ VCR Female
Barocel 7100 – 0.1mbar DN 16 ISO-KF W603325120 10.00
Pa
DN 16 ISO-KF (NW16)
Barocel 7100 – 0.1mbar 8VCR W603325220 10.00
Pa
8″ VCR Female

Data sheet

BAROCEL-7000-Series-Gauge-Product-Datasheet

Instructions Manual

EtherCAT Barocel 7025- 7045- 7100-Instructions

Barocel 7045 Gauge-Instructions

Barocel 7100 Gauge-Instructions

Scroll to Top