AIM Series

Part Number: D14558880, D14611880, D14643880, D14671880, NRA737880

Broad Range Vacuum Gauging

When measuring pressure over a large range and requiring exceptional accuracy throughout, broad range vacuum gauges are the ideal option. To guarantee the precision and control of your system, you need trustworthy vacuum gauges. The AIM Series Cold Cathode Gauge, the WRG Series Cold Cathode Combination Gauge, and the APG Series Pirani Gauge are some of our vacuum gauging options.

AIM Series Cold Cathode Gauge

The vacuum range covered by Edwards Active Inverted Magnetron (AIM) Gauges is 1 x 10-2 to 1 x 10-9 mbar, with reliable measurements. These gauges have shown to be dependable and robust in a variety of settings, including industrial operations and research instrumentation.

The output of the AIM-S gauge is an S-shaped analog signal. The AIM-X Gauge is a compact instrument that combines a gauge controller with an inverted magnetron gauge head. It may be easily integrated with a computer or PLC thanks to its linear output.

Because of their extremely low external magnetic fields, the SL and XL versions are perfect for use with delicate analytical instruments or in situations where the gauge must be installed close to a turbomolecular pump.

Category:
Enquiry

Features and Benefits

Drive electronics are integrated into the gauge head, saving important rack space and lowering system costs.
Integral low output impedance A faraday shield allows for extended wire runs (up to 100 meters) and offers a high level of noise protection.
Version XL, with a low magnetic field, is intended for delicate uses like electron microscopy and mass spectrometry.
It is possible to quickly exchange tubes without pre-calibration when they have interchangeable bodies.
CSA and CSA/US approved; satisfies safety standards for measuring electrical equipment.

Specifications

General Product Information

Connection Vacuum Inlet Flange DN 25 ISO-KF (NW25)
Weight 0.810 kg
Supply Voltage DC 13.5-36V
Dimension Length 0.079 m
IP Rating IP40
Supply Frequency DC Voltage
Dimension Height 0.116 m
Dimension Width 0.079 m

Environmental Conditions

Temperature Ambient Operation Max 333.15 K
Temperature Ambient Operation Min. 278.15 K
Temperature Ambient Storage Min. 273.15 K
Temperature Ambient Storage Max. 343.15 K

Classification

Product Pressure Range High Vacuum – 1*10-3 – 1*10-7 mbar


Ultra High Vacuum – 1*10-7 – 1*10-11 mbar


Principle Of Measurement Cold-cathode vacuum gauge (IM inverted magnetron)

Performance Data

Measurement Uncertainty >1×10-8 mbar ±30%
Power Consumption Max 2W
Pressure Measurement Max. 1.00 Pa
Pressure Measurement Min.. 1.000 × 10⁻⁷ Pa

Operation Conditions – Limitations

Temperature Baking Max. (Elec. Removed) 423.15 K
Pressure Inlet Max Overpressure 1.000 × 10⁶ Pa

Connectivity – Communication Interface

Communication Interfaces Customer 0-10 V (analog output – S-shape)
Connection electrical comms interface connector RJ45 (FCC 68) – Female
Setpoint Quantity 1
Status Indicator LED

Material of Construction

Material Abbreviation St St

Variants

Variant Gauges AIM-S (S-shape 0-10V output)

Variants

Short Description Part Number Connection Vacuum Inlet Flange
AIM-S – NW25 – St St D14641000 DN 25 ISO-KF (NW25)
AIM-S – NW25 – St St – factory calibration D1464100C DN 25 ISO-KF (NW25)
AIM-X – NW25 – St St D14642000 DN 25 ISO-KF (NW25)
AIM-X – NW25 – St St – factory calibration D1464200C DN 25 ISO-KF (NW25)
AIM-SL – NW25 – St St D14644000 DN 25 ISO-KF (NW25)
AIM-XL – NW25 – St St D14645000 DN 25 ISO-KF (NW25)
AIM-XL – NW25 – St St – factory calibration D1464500C DN 25 ISO-KF (NW25)
AIM-S – DN 40 CF – St St D14661000 DN 40 CF (2.75″)
AIM-X – DN 40 CF – St St D14662000 DN 40 CF (2.75″)
AIM-XL – DN 40 CF – St St D14665000 DN 40 CF (2.75″)
AIM-SI1 – NW25 – St St D14671000 DN 25 ISO-KF (NW25)

Data Sheet

AIM-Active-inverted-magnetron-gauge

Instructions Manual